Last updated: 6th July 2026 · Reviewed against National Measurement Institute of Australia reporting standards and peer-reviewed literature
Quick answer: No accredited Australian laboratory will issue a written report certifying honey above TA35+. When a jar is labelled TA50+, TA60+, or TA70+, that number was produced by extrapolating beyond the range the test method was calibrated and validated for — not by a certified measurement. The National Measurement Institute of Australia (NMI), the country’s peak measurement authority, caps its own reports at “>35% Total Activity” for exactly this reason. This page explains the method, shows the primary sources, and gives you three questions to ask any brand selling a rating above that line.
Total Activity (TA) is a measurement of antibacterial strength in honey, expressed as phenol equivalence. A honey with a TA of 30 kills bacteria as effectively, in a laboratory assay, as a 30% phenol (carbolic acid) solution. Phenol was chosen as the reference substance because it was one of the earliest standardised antiseptics, giving scientists a stable benchmark to compare honey against.
The method is not new or unusual — it is the same broad family of assay used to certify New Zealand Manuka honey’s UMF™ rating, and it has been in continuous use since it was first published in 1991.
This is the method described in the foundational paper: Allen, K.L., Molan, P.C., and Reid, G.M. (1991), A survey of the antibacterial activity of some New Zealand honeys, Journal of Pharmacy and Pharmacology, 43, pp. 817–822.
Here is the detail that the entire TA50+/TA70+ question turns on: the reference curve the test is built on only goes up to a 7% phenol standard.
That means the assay is only validated — proven accurate by direct comparison against known standards — within roughly that range. When a honey sample produces an inhibition zone larger than the strongest phenol standard in the test, the laboratory has no calibration point to compare it to. The result has to be extrapolated: mathematically projected beyond the region the curve was actually built from.
Australia’s National Measurement Institute — the government body responsible for measurement standards nationally — addresses this directly in its own reporting language. NMI’s official position, stated on its test reports, is:
“Results calculated above the standard curve and beyond the linear range of the standard curve are designated >35% Total Activity.”
In plain terms: the NMI will not print a specific number above TA35+. It will only confirm that a result exceeds that threshold. A result reported as “>35%” could reflect an actual honey performance of 36. It could reflect 80. The assay, run this way, cannot reliably distinguish between them — so Australia’s national measurement authority does not attempt to.
This is not a conservative labelling choice. It is a direct consequence of how the assay behaves once you push it past the range it was built and tested against.
Australian eucalyptus honeys (jarrah, marri, blackbutt, red gum) are rated using TA. New Zealand Manuka honey is rated using either MGO (methylglyoxal concentration, measured directly in mg/kg) or UMF™ (Unique Manuka Factor, a composite standard incorporating MGO alongside authenticity markers). These are three different measurement systems, built around different chemistry:
Because these systems measure different things through different methods, converting cleanly between them isn’t straightforward — and the UMF Honey Association, the body that owns and administers the UMF™ standard, says so explicitly:
“MGO and NPA are single compounds measures and cannot convert to the UMF™ rating.” — UMF Honey Association, official FAQ
If the organisation that owns the Manuka rating system states plainly that MGO doesn’t convert to UMF, a conversion table between TA and MGO — two entirely different measurement systems, from two different honey categories, using two different testing technologies — stands on no firmer ground. Any chart presenting “TA50+ is equivalent to MGO 4000+” should be read as a marketing device, not a scientific reference.
Independent of what any single lab report says, it’s worth asking: has any published study ever recorded — let alone validated — a TA rating in the 50s, 60s, or 70s?
The published literature says no.
| Study | What it found |
|---|---|
| Cokcetin et al., PLOS ONE (2016) — the largest peer-reviewed survey of Australian medicinal honey antibacterial activity | Highest recorded activity across the sample set: ~26% phenol equivalent |
| Green, Dods & Hammer, PLOS ONE (2020) — 69-honey assay validation study | Phenol-equivalence values ranged 0–48.5%, mean 34% — and this study was explicitly designed to test the limits of the assay |
| Western Australian Department of Agriculture survey (Manning & Mercer), 342 samples | Jarrah and marri averaged 30.2% and 31.1% phenol equivalent respectively |
| Irish, Blair & Carter, PLOS ONE (2011), 477-honey Australian flora survey | Marri median 25.7% phenol equivalent — the highest median recorded in the survey |
No peer-reviewed study has calibrated the phenol assay beyond 7% phenol. No published research has validated a reading at TA50, TA60, or TA70. The highest all-time reading in the most rigorous validation study specifically built to stress-test this method topped out at 48.5 — and that was the ceiling of an outlier, not a typical result.
The equivalency tables some brands publish — claiming, for example, that TA70+ corresponds to a specific MGO figure — are not derived from any published research. They cannot be, because no study has established what a reading above the validated range actually corresponds to in the honey.
A TA rating isn’t a fixed property stamped permanently onto a batch of honey — it’s a measurement, taken at a particular moment, using a particular method, on a particular sample. That leaves room for the result to be shaped, without anyone technically lying. None of what follows is illegal. It also isn’t rigorous.
1. Testing at the moment of harvest, not the moment of sale. A large share of Australian eucalyptus honey’s antibacterial strength comes from hydrogen peroxide, generated by an enzyme (glucose oxidase) that bees add to nectar. This activity is measurably highest when honey is fresh, and peer-reviewed research confirms it degrades over time — in some cases by up to 100% — and more quickly at warmer storage temperatures. Testing on harvest day captures a peak the consumer will never actually receive.
2. Never re-testing. Once a flattering result exists on paper, there is a direct commercial incentive not to test the same honey again later — because a second test, after time and transport, will very likely read lower. If it isn’t tested again, the original number is never technically disproven.
3. Exploiting varietal decay curves. Different honey varietals behave differently over time. This is where the science gets genuinely interesting: manuka’s activity is non-peroxide (MGO-based) and actually rises over time, while the peroxide-driven activity in jarrah, marri, blackbutt, and red gum declines from its peak and then stabilises at varying rates depending on the varietal. Testing any peroxide-dependent honey at exactly the right moment — immediately post-harvest — captures a transient high that isn’t representative of the honey a customer will eventually receive.
4. Handling and transport. Peroxide-based antibacterial activity has been shown in peer-reviewed research to be significantly more stable at refrigerated temperatures (4°C) than at room temperature (25°C). Temperature-controlled storage and air freight preserve more of a honey’s tested activity than months in an unrefrigerated shipping container. The certificate doesn’t change to reflect the journey — only the honey does.
5. Selecting the most generous laboratory. Because results above roughly TA35 require extrapolation rather than direct calibration, different laboratories can produce different extrapolated numbers from the same sample. Submitting honey to multiple labs and publishing only the highest number returned is a documented industry practice — chosen for the answer, not the rigor.
One Australian brand’s product listing for a “TA70+” honey describes it in its own headline as “the highest Total Activity rating we have ever seen.” Elsewhere on the same product page, the same brand states the batch is “independently tested and certified to confirm its TA50+ rating.” Both claims appear on the identical page, for the identical product, without reconciliation. That twenty-point gap between the marketing headline and the brand’s own certification claim is exactly the kind of inconsistency that a validated, single, certifiable number should make impossible — and exactly the kind that extrapolated, uncertified numbers make routine.
A specific, verifiable answer to all three is the minimum bar for a TA claim to mean anything:
If a brand can’t answer all three specifically, the number on the label is a marketing decision, not a laboratory result.
Australian Wildflower’s own Jarrah has returned a laboratory reading of 53.8% phenol equivalence, tested by ALS New Zealand using the same Allen/Molan/Reid phenol-equivalence method described above. We do not put that number on the label.
Not because the honey doesn’t perform that way on that assay, on that day, in that lab. It’s because a single high reading, taken with a method that stops being reliably calibrated well before that point, is not the same thing as a certified, repeatable measurement. We hold our own labelling to the same ceiling the National Measurement Institute holds itself to: TA35+, the highest figure an Australian accredited body will put its name to in writing.
Every batch we produce is tested — pre-extraction and again post-packing — by independent, accredited laboratories, and the results are published by batch number at our Transparency Hub. The original signed laboratory reports, not just our summary of them, are available to any customer who requests them, at no charge and without justification. We think that’s the difference between a rating and a claim: a rating survives someone actually checking it.
A label reading “TA50+” claims the honey performs, in an antibacterial assay, at a level equivalent to a 50% phenol solution. However, no Australian accredited laboratory will issue a certified report stating a specific number that high — the phenol-equivalence test used to generate TA ratings is only reliably calibrated up to approximately TA35. A TA50+ claim is necessarily based on an extrapolation beyond that range, not a certified measurement.
The honey itself is real; the certified number is the issue. No peer-reviewed study has validated a phenol-equivalence reading anywhere near TA70, and Australia’s National Measurement Institute will not print a specific figure above TA35+ on its own reports. A TA70+ claim on a retail label has not been produced by the same certification process that governs ratings up to TA35+.
Because the assay’s calibration curve is built from phenol reference standards that only extend to 7% phenol concentration. Results that would place a honey above roughly five times that reference point fall outside the range the curve was built and validated against, so the NMI reports them only as exceeding the threshold, not as a specific number.
Up to the certifiable range (approximately TA35 and below), yes — a higher TA reflects greater measured antibacterial performance. Above that range, a higher printed number reflects a larger extrapolation, a different testing lab’s methodology, or the timing of when the sample was tested — not necessarily a stronger honey.
TA, MGO, and UMF are three different measurement systems. TA is a phenol-equivalence performance assay; MGO is a direct chemical concentration measurement; UMF is a composite standard built on MGO plus two additional authenticity markers. The UMF Honey Association states explicitly that MGO does not convert to UMF — and by the same logic, published “TA to MGO” equivalence tables have no scientific basis, since they attempt to convert between systems that don’t share a common unit of measurement.
Yes — a single reading on a given day, from a given sample, can produce a number above 35. The issue isn’t whether an assay can ever spit out a bigger number; it’s whether that number can be reliably certified and repeated. Australia’s national measurement authority has determined it cannot, above this threshold, with the confidence required to put a specific figure on a signed report.
Have a TA claim you’d like sourced? Email info@australianwildflower.au — original laboratory reports for every Australian Wildflower batch are available on request, at no charge.
Read more in our blog “Why TA50+ and TA70+ Honey Ratings Are Not Scientifically Certifiable”
No products in the cart.