* TA50 honey rating not scientifically certified *
Summary
The Total Activity (TA) rating system for antibacterial honey is based on a laboratory assay that uses a phenol reference standard curve. The test method has a validated upper limit of TA35+. Australia’s National Measurement Institute (NMI) — the federal government body responsible for scientific measurement standards — explicitly states in its own test reports that results above this threshold fall outside the linear range of the standard curve and cannot be certified as specific values. No peer-reviewed scientific study has ever tested, calibrated, or validated the phenol equivalence assay at TA50+, TA60+, or TA70+. Honey labels bearing these ratings are not reporting certified measurements. They are reporting extrapolations beyond the validated range of the test.
What Is Total Activity (TA)?
Total Activity is a measure of a honey’s antibacterial potency, expressed as a phenol equivalence percentage. A TA rating tells you that the honey’s antibacterial strength is equivalent to a solution of phenol at that percentage concentration. TA30+ means the honey is as effective at killing bacteria as a 30% phenol solution.
The test used to determine TA is called the phenol equivalence assay (also known as the agar well diffusion assay or the Unique Manuka Factor assay). It is the industry-standard test used in Australia and New Zealand for grading antibacterial honey. The method works by:
- Preparing a 25% honey solution and placing it in wells cut into nutrient agar seeded with Staphylococcus aureus ATCC 25923.
- Placing a series of phenol standard solutions – at 2%, 3%, 4%, 5%, 6%, and 7% – in adjacent wells.
- Measuring the zones of bacterial growth inhibition after incubation.
- Comparing the honey’s zone of inhibition against the phenol standard curve to produce a phenol equivalence value.
This method can be reviewed in detail in peer-reviewed literature (Allen, Molan & Reid, 1991; Irish, Blair & Carter, 2011; Cokcetin et al., 2016) and is used by accredited commercial laboratories including the National Measurement Institute of Australia and ALS New Zealand – the same laboratory that certifies Manuka honey for the global export market.
The Scientific Limit of the Test
The phenol equivalence assay is calibrated against phenol standards that range from 2% to 7%. This standard curve is the backbone of the measurement. The zone of inhibition produced by a honey sample is mathematically interpolated against this curve to generate the TA number.
The problem with TA50+, TA60+, TA70+: These numbers fall far outside the range of the calibration curve. When a honey sample produces a zone of inhibition larger than what the 7% phenol standard produces, the laboratory cannot accurately place that result on the curve. The result is an extrapolation – a mathematical projection beyond the range where the assay has been validated.
The National Measurement Institute of Australia addresses this directly in its official test reports. The NMI states:
“Results calculated above the standard curve and beyond the linear range of the standard curve are designated >35% Total Activity.”
This means the NMI will not report a specific number above TA35+. It will only certify that the result exceeds the threshold. A result designated >35% could be 36%. It could be 80%. The test cannot distinguish between them with acceptable accuracy, so the NMI does not try. This is not a conservative commercial decision. It is a scientific one, made by the government body responsible for Australia’s measurement standards.
What the Published Research Actually Shows
The most comprehensive peer-reviewed study of Australian Leptospermum honey antibacterial activity is Cokcetin et al. (2016), published in PLOS ONEÂ (DOI: 10.1371/journal.pone.0167780). This study tested 80 Australian Leptospermum honey samples and measured their Non-Peroxide Activity (NPA), which uses the same phenol equivalence assay as TA.
The highest NPA recorded in the study was 26.3% – equivalent to TA26+. The study found a strong positive correlation (r² = 0.95) between methylglyoxal (MGO) concentration and NPA. The MGO concentrations associated with the highest-activity honeys in the study ranged up to approximately 1,100 mg/kg.
There is no published peer-reviewed scientific study that has:
- Tested honey with a validated TA rating above TA26% using the phenol equivalence assay
- Calibrated or extended the phenol standard curve beyond 7% phenol
- Scientifically established what MGO concentration corresponds to TA50+, TA60+, or TA70+
- Validated any alternative assay method capable of producing certified results at these levels
The equivalency tables that some honey brands publish – showing, for example, that TA70+ corresponds to a specific MGO value – have no peer-reviewed scientific basis. They are not derived from or consistent with any published research.
What Happens When the Same Honey Is Tested by Different Methods
Australian Wildflower tests all honey batches using two independent accredited laboratories – ALS New Zealand, National Measurement Institute (NMI) or Y-Trace – using two fundamentally different methodologies. Neither supports ratings above TA38.
Method 1 - Phenol Equivalence Agar Diffusion Assay (ALS New Zealand)
ALS New Zealand (IANZ ISO/IEC 17025 accredited) uses the inhibition zone assay – the same phenol equivalence method used by the NMI. It is the same laboratory that rates and certifies Manuka honey for the global export market. As described above, this method is calibrated against phenol standards from 2–7%, and results beyond the validated standard curve are extrapolations. The NMI, using this same method, will not certify a specific value above TA35+.
Method 2 - Broth Microdilution MIC Assay (Y-Trace)
Y-Trace uses a validated microplate broth microdilution assay developed by Green, Dods & Hammer (2020; DOI: 10.1371/journal.pone.0243246), adapted from the Clinical and Laboratory Standards Institute standard method (CLSI document M07-A11, 2018). This method works differently: it measures bacterial growth inhibition across a dilution series using a spectrophotometer, then converts the minimum inhibitory concentration (MIC) to a TA score using a banded mathematical conversion.
The conversion is a stepped IF statement producing discrete MIC values – 32, 16, 8, 4, 2, or 1 – which are then converted to a TA score. This is not a continuous scale. It is a banded method with defined thresholds. It cannot produce the granular specificity implied by labels such as “TA57+” or “TA63+” – those numbers simply do not exist as outputs of a banded MIC conversion. The method produces broad categories of inhibition, not precise points on a continuous scale.
What two independent methods agree on
When the same honey batch is tested by both methods, the results are complementary rather than identical – this is expected, as the assays measure inhibition differently. What both methods confirm is that the precise, specific numbers implied by TA50+, TA60+, or TA70+ labels have no basis in either methodology: the phenol equivalence assay cannot certify beyond TA35+ due to standard curve limits, and the broth microdilution assay produces banded categories, not the continuous high-precision values those labels imply.
Australian Wildflower does not market any honey above TA35+ – not because our honey does not produce higher readings on a given assay run, but because TA35+ is the highest value that Australia’s National Measurement Institute will certify in writing. That is the standard we hold ourselves to. A number on a label that no accredited government body will put its name to is not a measurement. It is a claim.
The Three Questions to Ask Any Brand Selling TA50+ or Higher
If you encounter a honey labelled TA50+, TA60+, TA70+, or any grade higher than TA35+, these are the three questions that determine whether the rating is a measurement or marketing:
- Which laboratory produced this result, and what is their accreditation?
The result should come from an ISO/IEC 17025 accredited laboratory with documented methodology. If the lab is not named, the result cannot be verified. - What is the exact batch number this result corresponds to?
TA ratings must apply to a specific tested batch, not to a product range or a “typical” result. Without a batch number, there is no way to match the claim to the test. - What is the specific test report, and can I see it?
The test report should be a signed laboratory document, not a marketing summary. It should include the method used, the date of testing, and the raw result. If the underlying report shows “>35%” – as NMI reports do for any result in this range – then the TA50+ number on the label was not produced by that report.
Why This Matters
Consumers purchasing high-TA honey for therapeutic purposes – wound care, immune support, digestive health – are making purchasing decisions based on the potency rating on the label. If that rating cannot be certified, the consumer has no reliable basis for comparison.
The TA rating system exists to provide a verifiable, standardised measure of antibacterial strength. When labels report numbers beyond what the measurement method can substantiate, the system stops working. A TA70+ label that is based on an extrapolation beyond the test’s validated range does not mean the honey is more potent than a TA35+ honey. It means the brand has printed a number the test cannot confirm.
Scientific measurement has limits. Those limits exist to protect the integrity of the result – and by extension, the consumer who relies on it.
References
- Allen, K.L., Molan, P., & Reid, G. (1991). A survey of the antibacterial activity of some New Zealand honeys. Journal of Pharmacy and Pharmacology, 43(12), 817–822. PMID: 1687577
- Irish, J., Blair, S., & Carter, D.A. (2011). The antibacterial activity of honey derived from Australian flora. PLOS ONE, 6(3), e18229. DOI: 10.1371/journal.pone.0018229
- Cokcetin, N.N., Pappalardo, M., Campbell, L.T., Brooks, P., Carter, D.A., Blair, S.E., & Harry, E.J. (2016). The antibacterial activity of Australian Leptospermum honey correlates with methylglyoxal levels. PLOS ONE, 11(12), e0167780. DOI: 10.1371/journal.pone.0167780
- Green, K.J., Dods, K., & Hammer, K.A. (2020). Development and validation of a new microplate assay that utilises optical density to quantify the antibacterial activity of honeys including Jarrah, Marri and Manuka. PLOS ONE, 15(12), e0243246. DOI: 10.1371/journal.pone.0243246
- Molan, P. (2008). Improvements to the UMF assay. New Zealand BeeKeeper, 16(7), 24–25.
- National Measurement Institute, Australia. Report of Analysis No. RN1396503. Sample Ref: 224568 (Jarrah Honey). Date Tested: 15-JUN-2023. Result: Total Antimicrobial Activity >35% (Method VM1.29).
Australian Wildflower is an independent producer of Western Australian native honey. We do not receive commercial benefit from the positions stated in this article. All test results referenced are available for inspection at australianwildflower.au.
This article is provided for informational purposes. It does not constitute medical advice.